How to connect the cold air tube / recirculation in heating ycsh How to do it…
How to lower the power of a 2kw and 5kw stationary heater step by step
🔥 Is your stationary heating too hot??
Las stationary heating 5 kW They offer a lot of power, but sometimes it can be excessive. If your device gets too hot, appears error E-05 due to overheating or do you want to reduce consumption, this guide shows you how to lower power safely.
In the models of 2kw we can make this same adjustment, useful in very small vehicles.
❓ Why lower the power of a stationary heater?
⚠️ Avoid overheating (error E-05)
And bad assembly, sharp curves or a boiler with restricted air passage can cause error E-05. Reducing power helps prevent it.
💡 When the model is too powerful
And you heating 5 kW is in a small vehicle, can generate more heat than necessary and not operate efficiently.
🌡 To reduce consumption in mild climates
In times of temperate climate, heating at full power causes continuous starts and stops. Reduce power stabilizes operation.
🛠 Methods to reduce power
- 🔧 From the screen settings: Some models like in this case, YCSH stationary heating with ch22 v2 screens, v2.1 and v3 allow manually regulate power.
- The process is very simple, on screen V2:
- You just have to enter the configuration menu by pressing and holding the key ⚙️
- SET appears on the screen 8, with the wheel we change it to SET 9. And we press OK
- We enter the password that is: 1234
- Now the screen will show us 12v, the following parameter (pressing OK) will show 5.0, (o 2.0 if it is 2kw) We press again and the parameter we were looking for will appear. 22ml
- We modify the 22ml by clicking on OK and turning the wheel, we left it at 28ml.
- We press the button “on” to confirm the change.
With V2.1 and V3 screen it is very similar:
- You have to press and hold the button ⚙️ configuration.
- We move through the menus until we find the internal configuration setting 🛠 (an icon with a wrench and a screwdriver)
- We enter the password 1234
- We move to the bomb icon and modify 22ml a 28ml.
Important: DO NOT modify the 5kw for a 2kw. to do this, the heating will not work optimally, and it will be filled with carbon.
This setting can also be applied to the 2kw model, modifying only the ML of the fuel pump.
💡 Use and maintenance tips
- Make it work maximum power at least 15/20 minutes to avoid carbon buildup, especially if it has been at minimum power all night.
- Review filters, ducts and air intakes periodically so that there are no fuel losses, dirt, obstructions.
❓ Frequently asked questions (FAQs)
🔹 Is it safe to lower the power of stationary heating?
Yeah, as long as the indications of this manual.
🔹 What is the difference between heating 2kW and one of 5kW?
The one of 2 kW is more efficient for small vehicles, while that of 5 kW is for large vans, campers and caravans in cold climates.
🔹 How to avoid error E-05?
Maintaining a clean installation, avoiding flow restrictions and reducing power if necessary.

This Post Has 0 Comments