Skip to content

YCSH CH25 screen instruction manual

Version: 15/10/2026_V1.0

1. Panel Screen Description

Once initialization is complete when turning on the device, The screen shows the following statuses:

  • Information displayed: Room temperature, Voltage, Clock, Power level / Set temperature. In case of breakdown, will show the corresponding error code.

Button Functions:

  • Power Button / Off (Power):
    • short press: Turn on the equipment (the screen shows ON).
    • long press (3 seconds): Turn off the equipment (the screen shows OFF).
  • Adjustment Buttons Above / Below (▲ / ▼): Adjust the Temperature and Power Level (+ / -).
  • Settings Button (Set): Allows you to enter and adjust system parameters.

2. Button Operation Instructions

Standby Status (Standby)

  • Temperature Adjustment / Power level: Use the buttons ▲ / ▼.
  • Configuration: Press the settings button.

Status On

  • Temperature Adjustment / Power level: Use the buttons ▲ / ▼.
  • Settings Button: No function in this state.

3. Special Features and Shortcuts

Manual Fuel Pump Operation (Purge)

  • State: waiting (Standby).
  • Procedure: Simultaneously press and hold the Power Button + Down Button (▼) during 5 seconds to enter the manual purge interface.
  • The screen will show 20sec. Press the buttons ▲ / ▼ to adjust pumping time.
  • Briefly press the Power Button to activate or deactivate pumping.
  • Press and hold the Power Button to go out.

Quick change between Manual Mode and Thermostatic Mode (Automatic)

  • State: Standby or On.
  • Procedure: Simultaneously press and hold the Power Button + Settings Button.
  • Automatic Mode (Thermostatic): Shows target temperature (ej. 30 °C).
  • Manual Mode: Shows power level (ej. P04).
  • Use: Manual mode is set by default.

Ventilation Mode

  • State: waiting (Standby).
  • Procedure: Press and hold the Power Button during 3 seconds until the word ON flash to enter ventilation mode.
  • Turn the knob or adjust the buttons to change levels (ej. P2, range of P1 and P5).
  • to leave, hold down the Power Button during 3 seconds until the word OFF I blinked.

4. Parameter Settings

To enter the parameter setting interface, long press the Settings Button in standby state (Standby). Use the buttons ▲ / ▼ to select between SET1 y SET4, and briefly press the Power Button to confirm the selection.

  • SET1 – Mode Selection:
    • Sample MT (Manual Mode). Usa ▲ / ▼ to change to AT (Automatic Mode) o ST (Start/Stop Mode – Start/Stop).
    • If you select ST, you can adjust the temperature difference with the buttons ▲ / ▼.
    • Press and hold the Power Button to save and exit.
  • SET2 – Carbon Monoxide Alarm Settings (CO):
    • Sample OFF. Usa ▲ / ▼ to change to ON.
    • When activating (ON), the CO icon will appear on the main screen.
    • Press and hold the Power Button to save and exit.
  • SET3 – Working Time:
    • Sample initially 0Min. Usa ▲ / ▼ to adjust the operating time (maximum 240 min).
    • Press and hold the Power Button to save and exit.
  • SET4 – Hardware Configuration:
    • Enter the password 1234. It will show values ​​like 12V, 5KW, 22ML.
    • Briefly press the Power Button to toggle between options and buttons ▲ / ▼ to modify the settings.
    • Press and hold the Power Button to save and exit.
    ⚠️ Attention: Function reserved for technical personnel. Improper use may cause malfunctions.

Important note: To save any modified parameters, it is mandatory to hold down the power button to confirm and exit. If the waiting time expires, the system will automatically exit without saving changes.

5. Other Features

  • Silent Mode Settings: (Turn off the voices)
    • Press and hold the button Below (▼) to turn silent mode on or off. The speaker icon will display a X when muted.
  • Network Bonding (Wi-Fi / APP):
    • State: waiting (Standby).
    • Press and hold the buttons ▲ + ▼ simultaneously to activate pairing mode. The screen will show wifi connect.
    • Open the application on your mobile phone, select the quick pairing option (One-click pairing), Enter the Wi-Fi network name and password according to the instructions and press confirm. Wait for the connection to complete automatically.
  • Screen Sleep Mode:
    • In waiting state (Standby): If no action is detected for more than 3 minutes, the screen will turn off completely.
    • In the on state: If no action is detected for more than 3 minutes, the screen will turn off leaving a light indicator with a breathing effect. Press any button to wake up the screen.

6. Error Codes and Troubleshooting

Error Code Fault Description
E00 Combustion sensor with open circuit
E01 Short circuit in load
E02 Supply voltage too high
E03 Supply voltage too low
E04 Short circuit in combustion sensor
E05 Overheat sensor with open circuit
E06 Short circuit in overheating sensor
E08 Short circuit in the electromagnetic pump
E13 Ignition failure (Can't light the flame)
E14 Unintentional flame extinction during operation
E18 Open circuit in glow plug (spark plug)
E19 Short circuit in glow plug (spark plug)
E21 Short circuit in main motor
E25 Atmospheric pressure sensor failure
E26 Atmospheric pressure sensor failure
E27 Overheating / Heater overheating
E29 Main motor does not turn
E32 Green line signal not detected